MPM Pressure Indicator/Transmitter with Alarms
DESCRIPTION

The MPM family of panel meters incorporates the use of a microprocessor and a solid-state, silicone piezoresistive sensor. The microprocessor allows for no trim pots, all digital calibration and overall product flexibility. The MPM family of panel meters combines an indicator, a switch, and a transmitter, with a large, vibrant 3 1/2 digit LCD display, all in a compact, 1/8 DIN enclosure. On the MPM2, set point settings are easily made by the on-board, push-button adjustments. The MPM family of pressure panel meters features a “zero” adjustment, making mounting orientation flexible and easy — and (on the MPM2) the two on-board LEDs allow for bright visual indication of when a Hi and/or Lo point has been achieved.

The MPM family of pressure panel meters may be ordered with dual relays providing for output switching. Typical applications would include those where a Hi and/or a Lo alarm point are important. The MPM family is available with a 2 or 7 amp failsafe configured relay. Models with relays also feature an easy-to-use, programmable deadband, which can be set for up to 25% of the range of the unit, in .100% increments.

Relative accuracy is 0.5% of full range. The unit is fully compatible with air and other inert gases. Ranges are available up to 20" WCD and 5 kPaD. An optional gasket is available in order to make the faceplate meet NEMA 4 requirements.


KEY FEATURES

3 1/2 Digit LCD Display
All models have a 31/2 digit LCD display. Also the use of a membrane style keypad makes wipe down very easy
.

Analog Outputs/Hi-Lo Relay Set Points
On certain models, a 4-20 mA or 0-5 vdc Analog output are available. Also, on certain models a hi and lo relay set point may be set by utilizing the “Mode” keypad button, as well as the “up arrow” keypad button. It allows you to easily scroll through the 31/2 digit display to arrive at a desired pressure set point.
Modus mpm-2


APPLICATIONS

HVAC Applications
Filter Monitoring
Flow Monitoring
Fan Static Pressure
Draft Pressures

Room Pressurization


Industrial Applications
Fume Hoods
Paint Spray Booth Filters
Bubbler Level Systems
Boiler (Draft) Pressures
Pollution Control Equipment (Baghouses)
HEPA Filter Monitoring (pharmaceutical and semiconductor plants)
SPECIFICATIONS  
Dimensions 1/8 DIN, 1.66" deep
(from base of pressure fittings)
Display 3 1/2 digit LCD display
Panel Cutout Dimensions 3.62" wide x 1.77" high Power Requirements 5 to 36 VDC for models without outputs
11 to 36 VDC for models with 4-20 mA
5 to 13 VDC or 12 to 32 VDC with Relay option.
Material ABS Plastic ULV94V-1 Power Consumption 30 mA for models without Relays (typ. < 1 watt)
100 mA for models with relays or Analog outputs
200 mA for models with relays and Analog outputs
Enclosure NEMA 4/IP 65 (front panel only)
with gasket accessory
Pressure Line Polarity automatically bi-directional
Measurement Ranges Available ±2" WCD
±5" WCD
±10" WCD
±20" WCD
±2 kPa
±5 kPa
(all units are bi-directional)
Warm-up Time 3 minutes to rated accuracy
Proof Pressure 3x Range Connections – Electrical
Power – screw terminal, 14-26 AWG
Outputs – screw terminal, 16-28 AWG
Operating Temperature Range 0 to 55°C   Pressure Lines
1/8 NPT (Female)
Storage Temperature Range -20 to 70°C Outputs (optional) Analog output (4-20 mA and 0-5 VDC)
Dual Relay Contacts, 2 Amp, SPDT
Dual Relay Contacts, 7 Amp, SPDT
Relative Humidity 10% to 90% User Adjustments Three push-buttons
(Zero, Mode Selection, Up-Arrow)
Set Points
Deadband
Analog Output Offsets
Relative Accuracy ±0.5%  
Span Tempco ±0.02%/°C
Zero Tempco ±0.05%/°C
       
       
ORDERING INFORMATION



Order Number (See Table below)
MPM-Model-Options-Additional Features
D-M-R-O-AF

EXAMPLE:
MPM-1-06EB-R7-N
Description
(one choice only)
Model
(one choice only)
Range
(one choice only)
Options
(one choice only)
Additional Features
MPM 1 = Base Model
Basic product with 3-1/2 digit LCD display.
Pushbutton Zero.
1/8 DIN case. 5 to 36 VDC power input.
See Note 1

06EB = +/-2" wcd
 
R2 = 2 alarm relays; high and low; 11-32 VDC; contact rating of 2 amps; user programmable deadband up to 25% of range.
Available on ALL MPM2 Models.

             
N = NEMA 4 Gasket
Available on all models.
  2 = Enhanced Model Basic product (MPM1) with front panel Hi and Lo alarm LED indicators and Hi/Lo alarm (setpoint) capability. Mode and +/- front panel buttons added.
See Note 2
08EB = +/- 5" wcd R7 = 2 alarm relays; high and low; 11-32 VDC; contact rating of 7 amps; user programmable deadband up to 25% of range.
Available on ALL MPM2 Models
 
     09EB = +/- 10" wcd  AO = isolated 4-20mA, 3-wire current loop output and 0-5 VDC output.
 
    11EB = +/- 20" wcd R2AO = R2 and AO combined
 
     09PB = +/- 2 kPaD  R7AO = R7 and AO combined
         
 
     11PB = +/- 5 kPaD    
Note 1: All models without option boards are 5-36 VDC; all option boards are 11-32 VDC
Note 1: All items in Options columns are only available on MPM2