| Product | THDx |
| Description | Remote Sensing Temperature, Humidity & Dew Point Recorder - 8" Chart |
| Image | ![]() |
| Features | The THDX is a uniquely versatile instrument. We have combined Temperature,
Humidity, and Dew Point Monitoring with an 8" chart and large digital display.
Alarms, locking door and keypad are also standard features of the THDX.
Accessories include extension cables for the instrument\'s probe for remote
monitoring applications.
|
| Notes |
|
| Specifications | Humidity Accuracy: ±2% from 0 to 60%,±3% from 60 to 95% Humidity Range: 0 to 95% (non-condensing) Humidity Sensor: Monolithic IC Humidity Sensor Temperature Accuracy: ±1.8°F (±1°C) Temperature Ranges: User selectable; -20 to +120°F, +40 to +110°F, -20 to +50°C, +5 to +40°C Temperature Sensor: Thermistor Alarms: Audio/Visual with High/Low set points (warning mechanism only, no controller function) Alarm is 90 decibels Ambient Operating Conditions: 0 to 95% RH (non-condensing), +32 to +122°F (0 to +50°C) Calculated Dew Point Accuracy: The Dew point is calculated and because of the nonlinearity of the equation the error that would result from the possible errors of temperature and relative humidity are approximately as follows: 95% to 30% RH = ±2°C ±3.6°F 30% to 10% RH = ±+4°C ±7.2°F 10% to 5% RH = ±+8°C ±14.4°F 5% to 0% RH = ±+49°C ±88.2°F Calculated Dew Point Range: -22 to +122°F, -30 to +50°C Average Response Times: 2.5 min at 63% of full scale Note: The THDx internally averages readings together. In battery mode the update rate is slowed to conserve power and since the unit takes 1 new reading per update, the response is also slowed. Battery power is recommended for back-up only. Average Battery Life: 1 day recording mode=2 months, 7 day=3 months, 31 day=4 months Calibration: User calibration, see calibration kit below Calibration Kit (optional): 12% (RH only-low end capsule) and 75% (high-end capsule 75% salt solution) 1 year shelf life, MSDS (material safety data sheet) available upon request Chart Size: 8" diameter Dimensions: 10.5" x 13.2" x 2.8" (26.7cm x 33.5cm x 7.1cm) Display Resolution: 1°F (1°C), 1% RH Display Type: LCD Mounting: Free standing or keyhole for wall mount Pen Life: 12 months depending on use Power Supply: 120V AC adapter, use 4 "D" batteries for back-up power. Power Cord Lenght: 2 meters Probe Dimensions: .91" diameter, 5.9" long (15.0 cm x 2.3 cm dia) 10" cord - RJ11 6 pin connector Recording Times: User selectable; 1, 7, and 31 day Warm Up Time: 15 minutes to stabilize Warranty: 1 year Enclosure Type & Weight:ABSWeight: 5 lbs without batteries (1.5 kg), 7 lbs with batteries (3.2 kg) Approvals: CE Includes: 1-point NIST Traceable Certificate of Calibration, two Pens, Box of 60 (-20 to +120/7 day) Charts, AC adapter, and Instructions |